What's Wrong With My Generator? - Generator Troubleshooting (2024)

Why Does My Generator Keep Shutting Off?

One of the most commonly asked questions regarding generator troubleshooting is “Why does my generator run for a short period of time, and then shut off?” We asked our most experienced technicians this question and they came up with quite a few of the most common reasons this may be happening and what you can do to remedy them.

What's Wrong With My Generator? - Generator Troubleshooting (1)

Overload

  • The first thing you should check is that you are not running more equipment on backup power than your generator can handle. If you are running too much equipment on too small of a generator, the generator may shut down in order to avoid putting too much stress on your appliances.
  • The only way to remedy a loss of power due to overload is to shut off the generator, reduce the load by unplugging unneeded appliances, and restart the generator. If you need help properly sizing your generator, check out the EMC Generator Sizing Webinar.

Fuel Shutoff Valve is Closed (Portable Generators)

  • If you are using a portable generator, there is a fuel shutoff valve that is usually only used when you are storing your generator for long period of time to prevent stale fuel from circulating unnecessarily. Check that this valve is not still shut and preventing the flow of fuel to your engine.
  • To remedy this, simply open the valve and restart the generator.

Fuel Level Too Low

  • Obviously, your generator will not run without fuel. If your generator only ran for a short period of time then won’t start again, make sure you check your fuel level.
  • To remedy low fuel, always make sure the fuel tank is full before running your generator. You can also choose to install a generator that is fueled by natural gas or liquid propane straight from the utility to prevent lack of fuel (disregarding extreme circ*mstances where the utility may fail).

Oil Level Too Low

  • Oil levels that are too low can cause generator shutoff. Generators will still start with low oil, but newer models have a “low oil shutoff sensor” that will automatically kill the engine when oil levels are too low in order to prevent running of the generator with no oil. Running with low or no oil can cause severe wear and destruction to certain parts of your engine.
  • To remedy low oil level, check oil level with the dipstick. If oil looks clean but the level is low, add more oil. If oil is dirty and at a low level, an oil change is necessary.
  • Sometimes your generator may display a low oil pressure alert when the pressure is actually fine. This may indicate that your oil pressure sensor is faulty and needs to be replaced.

Water Level Too Low

  • The rise in temperature without proper water levels in the radiator is too much for most generators to handle. Running at a high temp for any period of time is hard for the most sensitive parts of the engine, control panel, and voltage meter.
  • Check water level and add water if necessary.

Choke Position Open for Too Long (Portable Generators)

  • To start the generator the choke needs to be in full choke position. After a few minutes, change it to half, then after a few more minutes change it to run.
  • Generators can shut off after a few minutes of running if the choke is left in the full choke position for too long.
What's Wrong With My Generator? - Generator Troubleshooting (2)

Rodents

  • Generators are a warm home for small animals. And when they can’t find enough food, they will chew on any exposed wires or hoses causing electrical issues or fluid leaks.
  • To remedy rodent infestations, remove the rodents and replace any wires or hoses that have been chewed through. Setting rodent traps to catch any future small animals before they make a home in your expensive generator may be a good idea as well.

Faulty/Dirty Spark Plugs

  • If you have an issue with dirty or faulty spark plugs, you may hear a crackling noise and see your generator shut down after only a few seconds of running.
  • To fix a spark plug issue, the most foolproof way would be to replace them with brand new ones. However, some spark plugs can become dirty and work like new if cleaned and re-installed.

Clogged Air Filter

  • Engines need clean air to circulate in order for all parts to work in harmony. A clogged air filter prevents the correct amount of clean air from circulating throughout the engine.
  • This fix is easy. Clean or replace your air filter for better air circulation.

Dirty Fuel Tank/Pipes

  • Pressure can get locked in your fuel tank, dust or debris can cause restrictions, or your pipes can become damaged and leak. This makes it hard for the proper amount of fuel to circulate.
  • To remedy a fuel system issue, first start with checking the fuel cap vent for any clogs. If all looks well with the fuel cap; check the fuel tank for sediment, bad fuel, etc. (See our article on maintaining diesel fuel here!) If the fuel tank looks dirty, cleaning the fuel tank and conditioning the fuel is a good idea. It is also a good idea to release pressure in the fuel tank and inspect all the pipes before each use.
What's Wrong With My Generator? - Generator Troubleshooting (3)

Dirty Carburetor

  • Bad fuel in the carburetor can cause the volatile ingredients from fuel evaporate from the accumulated gas in the carburetor to form a thick mixture that sticks in the carb and causes a disruption in the fuel supply.
  • The easiest way to remedy this is to keep your carburetor clean. If a carburetor is left dirty for too long, you may need to end up replacing the carburetor.

Battery Issues

  • Usually battery issues begin with your battery charger. Your charger could be faulty, your installer could have put the charger on the same circuit as the block heater (causing the breaker to trip), or you could have gotten a faulty battery.
  • Check the battery charging source to make sure it is not faulty. It may need to be replaced. If charger is not faulty check circuitry for overload. If circuits are not overloaded and the charger is working as it should, then you should replace the battery.

Block Heater Issues

  • Block heaters keep the liquid in your engine around 100-120oF. This allows for quick startup and lubrication of critical parts. If your block heater is faulty, your generator may try to start, then shut off due to lack of fluid circulation, especially in colder temperatures.
  • The only way to fix this problem is to install a new block heater.

Engine Fault

  • Engine fault is hard to diagnose when you are not an experienced technician. If you have tried all the above steps and your generator still will not run for extended periods of time, engine fault may be the culprit.
  • If you suspect engine fault, the best idea is to call an experienced technician to come take a look.

Exhaust System Fault

  • A fault in the exhaust system can cause a generator to fail after a few minutes due to a buildup of exhaust causing a fault in the noxious emission sensors.
  • This is a critical issue that needs to be dealt with by a professional.

Electrical Problems

  • Electrical problems can happen in any part of any circuit or wiring of your generator. Electrical issues are not to be dealt with by unexperienced laypeople.
  • This issue needs an experienced technician or electrician to come and troubleshoot.
What's Wrong With My Generator? - Generator Troubleshooting (4)

Sensor Failure

  • Newer generator models have a lot of sensors. Sometimes if one sensor is failing it can set off a cascade of other issues in other sensors. Usually sensors are the most expensive part of a generator to repair or replace.
  • The only way to fix a faulty sensor is to replace it. After replacing the sensor, the control panel may need to be reprogrammed to acknowledge any changes made before it will start working correctly. An experienced generator technician can help with any sensor replacements or reprogramming.

Are You Having Problems With Your Generator? We Can Help!

Call 800-595-5315 Or Connect With Our Expert Technicians Here:

Other Articles

What's Wrong With My Generator? - Generator Troubleshooting (8)

Conrad Petersen

Lead Generator Technician

Conrad has over 10 years of experience in power generation. He graduated from Universal Technical Institute, and has a master certification from Generac. He loves the great outdoors and spending his time camping and fishing.

What's Wrong With My Generator? - Generator Troubleshooting (2024)

FAQs

What's Wrong With My Generator? - Generator Troubleshooting? ›

Battery failure is the most common generator issue. Batteries wear down with age, providing less and less power as time goes on. Knowing the service life of your generator's battery will ensure you know to replace it before it stops working.

What is the common problem of generators? ›

Battery failure is the most common generator issue. Batteries wear down with age, providing less and less power as time goes on. Knowing the service life of your generator's battery will ensure you know to replace it before it stops working.

How to diagnose generator problems? ›

Luckily, most of these issues are easy to fix yourself!
  1. Check the Fuel Tank. The first place to look if your generator won't start is the fuel tank. ...
  2. Check the Oil Level. ...
  3. Check the Start Switch. ...
  4. Check the Choke Valve Switch. ...
  5. Check the Spark Plug. ...
  6. Check the Carburetor. ...
  7. Check the Fuel Valve. ...
  8. Check the Ignition Coil.

What is the most common reason a generator won't start? ›

Battery Failure

One of the most common reasons a generator will not start is due to a battery failure. Often this could be caused by a loose connection or a sulfation build-up (a build-up of lead sulphate crystals on the plates of lead-acid batteries).

How to fix a generator not producing power? ›

Use a multimeter to find a blocked circuit before winding and connecting it. If the failure is due to poor contact, clean the surface layer until it's flat. At this point, the connection should be tight again. If your generator runs but no power is produced still, your generator's wiring may be fried and unusable.

What is the most serious fault in a generator? ›

Hence, generators are grounded in the appropriate manner, where their SLG current is limited (usually below the generator nominal current). LLLG (line to line to line and ground)is the most severe fault for generators and will damaged maximum to generator with same current(fault) level of other types of faults.

What is the common cause of generator failure? ›

Battery failure is the most common cause of generator failure. In most cases, battery failure is caused by loose connections or sulfation buildup — a condition where lead sulfates accumulate on battery plates.

What is the main fault of a generator? ›

The first generator problem that can arise are leaks. A generator may at times experience fuel, coolant, or oil leaks, but the good news is that these can usually be prevented by performing regular maintenance checks.

What are the symptoms of a bad generator? ›

We recommend regularly inspecting your generators to look for signs it may need repair, such as:
  • Visible Enclosure or Electrical Component Damage. ...
  • Slow Starts. ...
  • Low Power Flow. ...
  • System Alerts. ...
  • Fluid Leaks. ...
  • Battery Charging Issues.

How do you force start a generator? ›

Pull recoil cord

Pull the recoil cord until you feel a bit of resistance and then let it go back. If the engine doesn't start, try pulling the cord again. PRO TIP: If the engine doesn't start, move the choke to "half run" and pull the recoil cord again.

What possibly causes for a generator to stop suddenly when loading? ›

Check the fuel gauge for very low fuel levels in the tank. Look for fuel pipe restrictions, bends or damage that may be preventing sufficient fuel getting through to the engine. Also, sediment in the fuel tank may also be causing the issue.

Is there a reset button on a generator? ›

Steps to Reset

For most models, it's located on the control panel. Turn Off the Generator: Ensure that the generator is turned off. This is a crucial safety step before attempting any reset procedure. Press the Reset Button: Hold down the reset button for a few seconds.

How do I get my generator to work again? ›

Just like your car, if your generator won't start, it could be due to a dead battery or faulty connections. Try charging the battery via a 12-volt DC outlet or give it a jump courtesy of your car battery. If that doesn't work, then the battery is not likely the problem.

How would you get a generator to work after it has lost all of its residual magnetism? ›

Restoring this residual magnetism is possible and is sometimes referred to as "flashing the exciter field". To restore the small amount of residual magnetism necessary to begin voltage buildup, connect a 12 volt battery with a current limiting device to the exciter field while the generator is at rest, as follows: 1.

What is the most common problem with generac generators? ›

The overwhelming majority of Generac generator failures have to do with an old or damaged battery. Generator batteries should be changed every two years at an absolute minimum. Coolant levels. Low coolant levels will trip a sensor and force the generator into a “no start” state.

What are the bad things about generators? ›

Are Generators Dangerous?
  • The Potential Dangers Of Using A Generator. While generators are perfectly safe when utilised properly and placed in safe areas, there are always issues that can arise as with any machine, some more serious than others. ...
  • Carbon Monoxide Poisoning. ...
  • Electrical Hazards. ...
  • Fires And Explosions. ...
  • Conclusion.

Top Articles
Latest Posts
Article information

Author: Golda Nolan II

Last Updated:

Views: 6336

Rating: 4.8 / 5 (58 voted)

Reviews: 81% of readers found this page helpful

Author information

Name: Golda Nolan II

Birthday: 1998-05-14

Address: Suite 369 9754 Roberts Pines, West Benitaburgh, NM 69180-7958

Phone: +522993866487

Job: Sales Executive

Hobby: Worldbuilding, Shopping, Quilting, Cooking, Homebrewing, Leather crafting, Pet

Introduction: My name is Golda Nolan II, I am a thoughtful, clever, cute, jolly, brave, powerful, splendid person who loves writing and wants to share my knowledge and understanding with you.